Vacuum cleaner air performance comprehensive testing equipment
Vacuum cleaner air performance comprehensive testing equipment
Vacuum cleaner air performance comprehensive testing equipment
Vacuum cleaner air performance comprehensive testing equipment
Vacuum cleaner air performance comprehensive testing equipment
Vacuum cleaner air performance comprehensive testing equipment

Vacuum cleaner air performance comprehensive testing equipment

Description:

The air performance test bench is manufactured in accordance with IEC60312, IEC62885, F431-21 \ F558-17 standards (European and American standards), mainly for data analysis and collection of voltage, current, input power, power factor, suction power, flow rate, vacuum degree, and efficiency of vacuum cleaners.

Telephone

+8675526585726

Email

sales@damslab.com

DESCRIPTION

The vacuum cleaner air performance test bench is manufactured in accordance with IEC60312, IEC62885, F431-21, and F558-17 standards (European and American standards), mainly for data analysis and collection of vacuum cleaner voltage, current, input power, power factor, suction power, flow rate, vacuum degree, and efficiency.

The testing equipment is controlled by an industrial computer and displays the tested items and data on a 17 inch monitor. Through automatic calculation and real-time data collection on the computer, relevant test parameters and data are automatically recorded, and test reports and curves can be output through USB.

It adopts a one to two dual mode control and testing, integrating European standard testing mode and American standard testing mode. Commonly used for air data testing of clean electrical appliances. The testing equipment is suitable for use by various manufacturers and testing institutions of vacuum cleaners, cleaning appliances, etc

Main technical parameters;

1. Test station: Single station European standard/Single station American standard

2. European standard pressure equalization box: 500X500X500 American standard pressure equalization box: 457.2X457.2X254 Unit: MM

3. Detection mode: European standard, American standard 4, Drive motor: Servo motor

5. Flow meter: (0.5-5) cubic meters per minute, accuracy: ± 0.075%

6. Vacuum pressure gauge: (-50-0) Kpa, accuracy: ± 0.075%

7. According to the requirements of American and European standards, the American standard is a rotating orifice plate, and the orifice plate series sizes (mm) are 63.5, 57.2, 50.8, 44.5, 38.1, 34.9, 31.7, 28.6, 25.4, 22.2, 19.0, 15.8, 12.7, 9.5, and 6.3

8. Power supply: AC 0-250V DC 0-60V Current detection range: 0-30A

43519de778d520c624a7aa462dfa4f96_638720185600446594_1.png

Main functions:

1. Through servo motor control, the air inlet valve is automatically adjusted. The PLC collects data on the input voltage, current, speed, input power, power factor, frequency, output power, and vacuum degree of the vacuum cleaner during testing. Relevant test data can be exported through USB.

2. Draw the relationship curves between vacuum degree, input power, suction power, efficiency, and air volume based on the data from each test

3. The device adopts a 17 inch touch computer display, which can display real-time test electrical parameters such as air volume, vacuum degree, input power, suction power, and efficiency; When the air duct is fully closed, test parameters such as vacuum degree and input power and record them.

4. The tested data can be stored and test reports and curves can be output according to user requirements.

5. Pressure equalization box: manufactured according to standards.

INQUIRY

Product*
Name*
Phone*
Email*
Company*
Content*
Copyright © 2025 Demasheng Measurement All Rights Reserved.  Technical Support: Chemical Instrument Network  sitemap.xml

+8675526585726

WeChat

WeChat

Please enter product name!
Please enter your name!
Please enter telephone number!
Please enter E-mail!
Please enter corporate name!
Please enter message content!
Product Name cannot be empty!
Name cannot be empty!
Please enter a valid phone number!
Please enter a valid E-mail!
Commpany Name cannot be empty!
The message content cannot be empty!
Submitted Successfully
Submission Failed