sales@damslab.com
+8675526585726
Vacuum cleaner performance testing bench (American, European, and national standards)
Vacuum cleaner performance testing bench (American, European, and national standards)
Vacuum cleaner performance testing bench (American, European, and national standards)
Vacuum cleaner performance testing bench (American, European, and national standards)

Vacuum cleaner performance testing bench (American, European, and national standards)

Description:

The vacuum cleaner performance test bench is manufactured in accordance with GB/T20291.1, IEC60312, IEC62885, F431-21 \ F558-17 standards (national standard, European standard, American standard). The test parameters of the vacuum cleaner performance test bench include voltage, current, input power, power factor, suction power, flow rate, vacuum degree, and efficiency of the vacuum cleaner.

Telephone

+8675526585726

Email

sales@damslab.com

DESCRIPTION

I. Overview

Vacuum cleaner performance test bench according to GB/T20291.1TheIEC60312IEC62885Manufacturing according to relevant testing standards such as national and European standards,The testing parameters for the vacuum cleaner performance test bench include the voltage, current, input power, and power factor of the vacuum cleanerInhalation work Rate, speed, flow rate, vacuum degree, and efficiency. The air performance testing platform adopts a one to two dual-mode control andTesting, integrating European standard testing mode and American standard testing mode.Can be switched between dual modes, with test data not affected by each otherinfluenceAccording to European standards IEC60312TheIEC62885Vacuum cleaner specialized testing equipment designed and manufactured in accordance with relevant standardsBe prepared. The relevant test data can be obtained through USBExporting test data and testing platforms are widely applicable to various vacuum cleaner manufacturers and inspectorsTesting the air performance of vacuum cleaners by testing institutions.

IIInstrument Description

1. Through servo motor control, the air inlet valve is automatically adjusted,PLC Collect the input voltage of the vacuum cleaner during testingData such as current, speed, input power, power factor, frequency, output power, and vacuum degree, as well as relevant test datacan pass throughUSBExport data.

2. Draw the relationship curves between vacuum degree, input power, suction power, efficiency, and air volume based on the data from each test

3. The equipment adopts17 Inch touch computer display, capable of real-time display of test electrical parameters, maximum/Minimum air volume, vacuum degree, and transmissionInput power, suction power, and efficiency; When the air duct is fully closed, the maximum is/zuiTest parameters such as low vacuum degree and input power, and record them.

4The tested data can be stored and test reports and curves can be output according to user requirements.

5. Pressure equalization box: manufactured according to standards

Temperature compensation and modification: according to IEC60312Chinese 5.2.8.4Adjust the atmospheric pressure density according to regulations

IIIParameter Description

1. Test items: voltage, current, power, power factor, vacuum degree, air volume, suction power, and efficiency;

2. The parallel detection data is calculated by the computer, and all characteristic curves are completed in one go.

3. Control method: Industrial computer+17 Inch touch screen display

4. adopt0.25 High precision vacuum sensor

5. Valve body control method:PLCElectric control valve(Switchable manual6.Controlled by servo automatic control equipment, the valve is fully controlledThe entire process of opening and closing can be tested, and the measured data can be retained or printed.

Technical Specifications:

1According to the relevant testing requirements of national and European standards, European standards BThe testing method is orifice plate type

2Inflatable chamber (pressure equalization box): The size and material are designed and manufactured according to relevant standards;

3Test pipeline: The test pipeline is formed by a throttle valve and a steel pipeline, with a measurement accuracy of±2%.

4Vacuum cleaner parameter tester:

Electrical parameters: AC voltage:AC10V--300V),


DC voltage:DC(0-60V)accuracy:0.2%

electric current:AC1A--30A),DC1A--30A)accuracy:0.2%Flowmeter:(0.5-5)cubic meter/Minutes, accuracy:±0.25 level

Vacuum pressure gauge:(0--100)Kilopascals, accuracy:±0.25 Level DC voltage:DC(0-60V)accuracy:0.2%

electric current:AC1A--30A),DC1A--30A)accuracy:0.2%Flowmeter:(0.5-5)cubic meter/Minutes, accuracy:±0.25 level

Vacuum pressure gauge:(0--100)Kilopascals, accuracy:±0.25 level

Test items: voltage, current, power, power factor, vacuum degree, air volume, suction power, efficiency. The size of the automatic control door valve is controlled by a computer to complete the full line special display curve at once

4. 1TheP1=f(Q)characteristic curve4.2ThePS=f(Q)characteristic curve4.3TheHm=f(Q)characteristic curve4.4=f(Q)Characteristic song

4.5 Vacuum degree testHmmax

4.6 Air volume measurementQmax 6Speed:r/min

4.7 Test standard basisGB/T20291.1TheIEC60312TheGB20291TheGB25441Waiting for standards


INQUIRY

Product*
Name*
Phone*
Email*
Company*
Content*
Copyright © 2025 Demasheng Measurement All Rights Reserved.  Technical Support: Chemical Instrument Network  sitemap.xml

+8675526585726

WeChat

WeChat

Please enter product name!
Please enter your name!
Please enter telephone number!
Please enter E-mail!
Please enter corporate name!
Please enter message content!
Product Name cannot be empty!
Name cannot be empty!
Please enter a valid phone number!
Please enter a valid E-mail!
Commpany Name cannot be empty!
The message content cannot be empty!
Submitted Successfully