4 Technical Indicators:
4.1 Test angle size: 1500x1500x1800mm;
4.2 Thermocouple: Diameter less than0.3mmThe thermocouple
4.3 Thermocouple Layout: All leads are connected to one wiring block
4.4 Temperature measuring copper sheet: diameter15mm, thickness1mmBrass sheet;
4.5 Temperature measurement points: 64 points
4.6 Test Angle Temperature Measurement Points: Point Layout Method100*100Mm full
4.7 Plywood: Thickness approximately20mmPlywood, coated with matte black paint on the front and gray film board on the back
5 Basic configuration:
5.1 Test one corner.
5.2 Spare copper sheets.
6 Installation connection:
After unboxing, connect the thermocouple wire plug with plug to the temperature measurement interface, and connect the tail end of the thermocouple wire with plug to the terminal on the back plate of the thermometer.
7 Operation Method:
1. Place the test sample on the testing corner as required and turn on the power supply;
2The thermocouple is led through the wire slot to the terminal on the back plate of the thermometer on the side plate;
3Measure the temperature of each point on the current measuring surface.