The battery short-circuit test chamber is suitable for lithium primary batteries and other primary batteries, as well as lithium-ion batteries (used in digital electronic products such as mobile phones, laptops, cameras, etc.), nickel hydrogen, nickel cadmium, and lead-acid batteries (used in products such as power tools, toys, electric bicycles, etc.), according to standards IEC60086-4: 2000、IEC62133: 2002、UL1642: 2006、SN/T1414.3-2004、GB31241-2022、GB/T 36972-2018 Conduct external short-circuit tests in accordance with the relevant requirements.
+8675526585726
13609623361@139.com
DESCRIPTION
Purpose:External short circuit test for lithium primary batteries and other primary batteries, as well as lithium-ion batteries (used in digital electronic products such as mobile phones, laptops, cameras, etc.), nickel hydrogen, nickel cadmium, and lead-acid batteries (used in products such as power tools, toys, electric bicycles, etc.)
Technical specification requirements:
1 Scope of Application
1.1 Applicable standard
The battery short-circuit test chamber is suitable for lithium primary batteries and other primary batteries, as well as lithium-ion batteries (used in digital electronic products such as mobile phones, laptops, cameras, etc.), nickel hydrogen, nickel cadmium, and lead-acid batteries (used in products such as power tools, toys, electric bicycles, etc.), according to standardsGB8897.4-2002TheGB/T18287-2000TheIEC60086-4: 2000TheIEC62133: 2002TheQC/T 743-2006TheUL1642: 2006TheSN/T1413-2004TheSN/T1414.3-2004TheGB31241-2022TheGB/T 36972-2018Conduct external short-circuit tests in accordance with the relevant requirements.
1.2 Test requirements
In the above standards, forhigh temperatureThe requirements for external short-circuit testing are slightly different, and the battery short-circuit test box meets all of the following test requirements:
1)The battery is(57±4)After reaching temperature equilibrium in an environment of ℃, withstand the total resistance of the external circuit at the same temperature0.1The short circuit of Ω continues until the temperature of the battery casing drops back to(57±4)After ℃, continue1More than hours.
2)A fully charged battery or battery pack(20±5)℃ or(57±4)℃,Relative humidity not exceeding75%Under the environmental conditions,The total resistance of the external circuit between the positive and negative poles of the battery or battery pack0.1Short circuit of Ω, short circuit test continues24Hours, or when the temperature of the battery casing drops below the peak value20%At the end of the experiment (monitored by thermocouples), take the test results with a shorter time.
PARAMETERS
Main technical parameters
1)Temperature range:RT+20℃~60℃
3)Temperature fluctuation: ±0.5℃
4)Short circuit station:1road
5)Temperature measurement station:1road
6)Short circuit resistance of each circuit:80Hao Ou ±20milliohm
7)Bottom area of short-circuit working chamber:600mm×600mm
8)Maximum applicable sample size:500mm
9)Space inside the temperature control box: not less than600*600*600mm
10)Observation window: double-layer anti riot glass design, size300mm╳300mm
11)Maximum short-circuit current:1500A,Maximum allowable passing current3000A,5Within seconds
12)Machine size: aboutW1200mm*D900mm*H2000mm(Vertical)
INQUIRY
+8675526585726
13609623361@139.com