The air performance test device for range hoods is a wind measurement system developed and manufactured according to standards such as GB/T 17713-2011 “Range hoods“ and GB/T14806-2003 “AC ventilators and their speed controllers for household and similar use“. This air performance test device is mainly designed for the “Exhaust Range Hood Air Performance Test Device“ in Appendix C of GB/T17713-2011 “Range Hood“ standard. This device can only be used for testing “Exhaust Range Hood“ and cannot be used for testing “Circulating Range Hood“.
+8675526585726
sales@damslab.com
DESCRIPTION
The basic testing principle is to simulate the actual working state of the test specimen in the testing wind tunnelChange the diameter of the orifice plate of the air outletThen measure itEach static pressure value of the air outletCalculate the corresponding value at this time using the standard formulaofflow coefficientAnd parameters such as air volume.
This device adopts computer automatic measurement and control method, which only requires manual installation and replacement of test samplesorifice plateThe entire process of testing a sample only takes ten minutes. It can measure the corresponding curves of static pressure and air volume, air volume and speed, current, power, efficiency, etc. It has the characteristics of convenience, speed, stability, reliability, and good reproducibility. Satisfy the testing and use of related products in scientific research and production processes.
1. Product Name:Air performance testing device for range hood
2. Model specifications:DMS定制
3. Standard basis: GB/T17713-2011TheGB/T14806-2003waitRelated product standards.
4. Applicable product: Range hoodPipeline typeVentilators, supply fans, etc.
5. Performance and feature requirements:
1) Automated testing, calculation, and data output are achieved through computers and their peripheral devices, with graphical display and printing of test results. The human-machine dialogue operation is simple, with high accuracy, saving time and effort.
2) Test items: P-Q characteristics (relationship between flow rate and static pressure), Q - η characteristics (relationship between flow rate and efficiency), synchronous measurement of the rotational speed, current, and power of the tested object.
II Overall Plan
This plan does not include the laboratory building structure, which will be constructed by the user according to standard requirements.
1.General laboratory requirements
Size:3500(Width) ×5000(Length) x 2800 (height) mm or more.
Wall: Smooth and flat, without any openings that affect airflow (air conditioning openings should not be blown directly).
Ground: The ground should be kept flat.
Temperature and humidity: When measuring air volume, the air temperature in the laboratory is 20 ℃± 5 ℃ and the humidity is 30% -80%.
Atmospheric pressure: an ordinary atmospheric environment with an altitude not exceeding 1000 meters.
INQUIRY