According to GB/T18801 Air Purifier, the test chamber is a device used to determine the limited enclosed space and standard test conditions of the purifier's ability to remove target pollutants from the air.
+8675526585726
sales@damslab.com
DESCRIPTION
Equipment Introduction
1. Equipment Introduction
This experimental system includes a laboratory, an air circulation device, an exhaust system, and a sampling device for adding samples
Composition of equipment and electrical control system.
2. Test method
This experiment is mainly divided into: natural attenuation test and total attenuation test
The natural attenuation test is as follows:
1) Place the air purifier to be tested on the test bench in the middle of the laboratory (except for vertical air purifiers), adjust the air purifier to the working state, check if it is running normally, and then turn off the air purifier;
2) Arrange the sampling points in a position that avoids the air inlet and outlet, with a distance of 0.5m from the wall and a relative height of 0.5-1.5m above the laboratory floor. One or more sampling heads can be installed at the same sampling point and connected to external sampling tubes;
3) Close the exhaust duct air valve, open the internal circulation duct air valve, start the auxiliary fan, use a high-efficiency filter to purify the air in the laboratory, and make the particle diameter 0.3MThe background concentration of particles above m is less than one thousandth of the initial detection concentration, and the air temperature and humidity in the laboratory are also measured;
4) Wait for the background concentration of particulate matter to decrease to an appropriate level, record the current background concentration of particulate matter, turn off the circulating fan and high-efficiency filter, start the household ceiling fan, and use the sampling device to place the smoke pollutant in the laboratory and allow it to enter the air vortex generated by the ceiling fan stirring. Stir for 10 minutes, and then turn off the household ceiling fan after the pollutants are mixed evenly;
5) After the ceiling fan is completely stopped, use a laser dust particle counter to measure the concentration of pollutants. Generally, at the beginning of the test, the concentration is 0.3MThe particle concentration of particles above m is 2000000 particles/L
Left and right, the value of the test point is used as the initial concentration in the laboratory;
6) After the initial concentration is determined, the detection experiment begins. During the detection experiment, the pollutant concentration is collected together for 2 minutes, and the measurement is carried out for 20 minutes. It is required that at least 9 data points have a concentration greater than twice the lower limit of the instrument measurement;
7) Record the laboratory temperature and humidity during the experiment;
8) Based on the measured data, the natural attenuation constant Kn can be calculated;
Total attenuation test
1) Conduct the test according to the provisions of (1-4) above;
2) After the household ceiling fan is completely stopped, the concentration of pollutants is measured using a laser dust particle counter. Generally, the test starts at 0.3MThe particle concentration of particles above m is 2000000 particles/L
Left and right, the value of the test point is used as the initial concentration in the laboratory;
3) After the initial concentration is determined, turn on the air purifier to begin the detection test. During the detection process, the concentration of pollutants is measured every 2 minutes and continuously for 20 minutes. At least 9 data points are required to have a concentration greater than twice the lower limit of the instrument measurement;
4) Turn off the air purifier and record the laboratory temperature and humidity during the experiment;
5) Based on the measured data, the total attenuation constant Ke can be calculated;
serial number |
volume/m3 |
size(longxwidexhigh)/m |
main purpose |
1 |
3 |
1.4x1.4x1.5 |
CCM loading test,CADRTesting experiment |
2 |
10 |
2x2x2.5 |
CCM loading test |
3 |
30 |
3.4x3.5x2.5 |
CADR testing experiment |
4 |
81 |
6x4.5x3 |
CADR testing experiment |
note:CADRIt is the abbreviation for clean air volume,CCMIt is the abbreviation for cumulative purification capacity, and the testing method is based onGB/T18801. | |||
Laboratory composition |
Experimental room, fluorescent lamp1.4mHousehold ceiling fans, test benches, power sockets, etc |
size |
V=3400W * 2500H * 3500L ≈30m3(The outer cabin user builds it themselves, with dimensions of)6-10meter length*6Meter wide*3-4.5High in height; ) |
leakage rate |
leakage rate<0.05 |
material |
8mm float glass, stainless steel inner wall material, observation window equipped with collection and sampling holes |
Equipment installation |
1. Reserve one on each side450*450(mm)Install the port as an internal air circulation inlet and outlet, and reserve a dedicated exhaust port near the top of the side; 2Install a sealed cabin door;3Reserved sampling holes and sampling holes(3+3)4Install one at the top1.4mHousehold ceiling fans and4 Taiwan40WFluorescent lamp; |
installation process |
All connection parts are sealed with silicone rubber strips and glass silicone to ensure the airtightness of the laboratory |
Air circulation device | |
Equipment Composition |
Circulating fan, pipeline, medium efficiency filter, high-efficiency filter, regulating air valve, etc |
Fan (technical parameters) |
Circulating fan: Air volume:1800m3/h; Full pressure:500Pa |
material |
The circulation pipes are made of stainless steel material; |
Equipment installation: |
Connect the air inlet of the circulating fan to the side reserved in the laboratory as the air inlet for air circulation, and install a damper. After the damper, install a filter with an efficiency of60%Medium efficiency filter; Then install a filter with an efficiency of99.9%Install a high-efficiency filter, then install a regulating valve, and connect the outlet to the installation port already reserved on the other side of the laboratory; |
installation process |
All connection parts of the pipeline are sealed with sealing strips and glass silicone to prevent the entry of external particles during the circulation process. |
exhaust system | |
System Composition |
Axial flow fan, damper, duct, adjustable louver, waterproof louver |
fan |
Axial flow fan: Air volume:1000m3/hFull pressure:300Pa |
material |
All pipelines are made of stainless steel material (or galvanized sheet) |
Equipment installation |
Connect one end of the pipeline to the reserved exhaust outlet of the tester, and install an adjustable louver at the exhaust outlet. Connect the other end to the air valve, and then connect it to the axial flow fan for outdoor exhaust; |
installation process |
The overall connection uses flange type connection, and all connection parts are sealed with sealing strips and glass silicone. The connection between all blades of the air valve is treated with sealing strips; |
Equipment Composition |
Console, electrical switch, power meter, button switch, computer, data collector, power meter, etc |
Electrical installation |
Compliant with electrical related standards |
Sampling and sampling device | |
Equipment Composition |
Sample addition device:Hongtashan brand cigarettes, vacuum pump, electronic cigarette lighter, camera tripod, and sampling port Sampling device: trachea, camera tripod. Overall design: The temperature and humidity are ensured by the outer cabin, and the humidifiers, dehumidifiers, heaters, and refrigerators are original from Siemens, GermanyCPUControl, SiemensPIDAlgorithm adjusts temperature and humidity to ensure precise control of the experimental environment within the standard range. |
main function |
Pollutant injection and collection of particulate matter use |