The Guangdong Demaisheng button power cord tension and torsion testing machine is based on IEC335-1, IEC60884, GB2099.1-2008, GB4706-2005, GB7000.1-2015; According to standards, the Guangdong Demaisheng button power cord tension and torsion testing machine is designed to test the torque of household and similar electrical appliances, and to ensure that the power cord clamping device is secure. The Guangdong Demaisheng button power cord tension and torsion testing machine uses the force generated by a torque motor to conduct a tension test on the power cord of the test sample. Considering that the power output positions of electrical products vary, this machine structurally installs the torque motor on a column with a movable sleeve, which is then mounted on a base with four wheels. The adjustment of the working head's position in the up, down, left, and right directions is very convenient.
+8675526585726
sales@damslab.com
DESCRIPTION
The DMS-LN key power cord tension and torsion testing machine from Guangdong Demaisheng uses the force generated by a torque motor to conduct a tension test on the power cord of the test sample. Considering that the power output positions of electrical products vary, this machine structurally installs the torque motor on a column with a movable sleeve, which is then mounted on a base with four wheels. The adjustment of the working head's position in the up, down, left, and right directions is very convenient.
1、 Overview:
According to IEC335-1IEC60884TheGB2099.1-2008TheGB4706-2005TheGB7000.1-2015;Designed to test the torque of household and similar electrical appliances and ensure the firmness of the power cord clamping device according to standards.
2、 Technical features:
1. Working power supply:220V~50Hz;
2. Tensile value:20NThe30NThe60NThe80NThe100NThe120N; Torque:0.08 NmThe0.15 NmThe0.25NmThe0.35Nm
3. ;0.01Tensile time:~999.9S
4. continuously adjustable0.01Torque time:~999.9S
5. continuously adjustable1Number of pulling cycles:999999 ~
6. Continuous setting and counting, automatically stopping when the set value is reached0Displacement: The photoelectric rotary encoder reads the displacement and changes generated before and after the sample test,~50.00mm
7. ,resolution is
8. 0.01mm
A set of lifting system.09. Number of tensile tests:9999~Pre set within the next time,
The number of pulling cycles is carried out electrically;10. Duration of each pulling force:1s;
The duration of tension and torque can be set.150011. The largest size of the sample platform: lengthX width1500(mm)
The platform size can be adjusted or disassembled for assembly as needed; The height of the test platform is electrically adjustable.12. Spare parts: for testing purposes10mm10thick glass
Block;160013. Size:1800×1200×(mm
14. )seamless welding2mmThick chassis, painted outer box. The transmission device, fixture, and weight are allSUS304
15.stainless steel
Tension and torque are achieved using weights
3、 Preparation before the experiment
1. Adjust the adjustment rod of the suspension weight steel wire rope. When the motor cam is at the lower limit point, apply force to the adjustment rod. At other positions, apply force to the sample tension rod.
2. Select tension and torque weights according to the sample requirements. When installing the torque weight, first turn on the power and press the torque fixture release button to release the torque arm wheel. Place the torque weight on the steel rope hook, then rotate the torque arm wheel to raise the weight to the corresponding height, and then pop up the fixture release button to reset it.
3. Adjust the position of the pull rod
When conducting a tensile test, it is required that the pull rod be aligned with the center of the pulled power cord. Adjustment steps: Rotate the handle to move the working head up and down, aligning the pull rod with the power cord, and at the same time, press the top block in front of the pull rod vertically against the power cord output surface.
5. Clamp the power cord tightly
Before clamping the power cord, first make a mark 20mm away from the outlet, then loosen the clamp of the pull rod, place the power cord into the clamp slot, tighten the power cord, and tighten the clamp bolt.
7. Pre set the number of tension times and torque time as required.
4、 Setting and presetting methods for counters and time relays:
1. Counter settings and presets: (Please refer to the counter manual for details)
a. Setting method and parameters: (Note: The upper panel of the instrument is the display mode, and the lower panel is the setting mode)
Press [MD] for three seconds to enter the setting mode → Display in [IN] → Press ▲ or ▼ to select [U] mode → Press [MD] again → Display in [CPS] → Press ▲ or ▼ to select [30] → Repeat this process → Press [MD] for three seconds to complete the setting program
Input Method IN - Select U
Counting speed CPS - select 30
Output mode OUT - Select F
Output time OUT. T select HOLD
Input Logic SG - Select PNP
Reset time RST - Select 20