Technical requirements for axial force testing device of fluorescent lamp holder: The fluorescent lamp holder with the test lamp head in place is subjected to a pressure acting on the center of the lamp head in the direction of its axis for 1 minute -------G5 lamp holder 15N -------G13 lamp holder 30N -------Single ended fluorescent lamp holder (G23, G10q, GR8, etc.) 30N Professional manufacturer of axial force testing device for fluorescent lamp holders
+8675526585726
sales@damslab.com
DESCRIPTION
Technical requirements for axial force testing device of fluorescent lamp holder:
The fluorescent lamp holder with the test lamp head in place is subjected to a pressure acting on the center of the lamp head in the direction of its axis for a period of time1min
-------G5lamp holder15N
-------G13lamp holder30N
-------Single ended fluorescent lamp holder(G23TheG10qTheGR8wait) 30N
-------The values of other lamp sockets are still under consideration
After the experiment, the distance between the lamp sockets should comply withIEC60061-2The relevant requirements are met, and the lamp holder should be undamaged.
The test lamp head used in this experiment should comply withIEC60061-3Data sheet in:
G5Lamp holder,7006-47C
G13Lamp holder,6007-60C
The test lamp heads for other lamp holders are currently under consideration
Test judgment: After the test, the single ended fluorescent lamp holder should not deviate from its position, and the fixed position should not deform for a long time. When the light source is reinserted, it will enter its predetermined position.