The Ceiling Fan Airflow Testing Device is constructed in accordance with the requirements of GB12021.9-2008 “Energy Efficiency Limits and Grades for AC Fans“ and GB/T 13380-2007 standard clause 6.7.2, as well as the laboratory requirements specified therein. Simultaneously meet the requirements of the current version of the above standards and the new version of the standards that are in the revision stage.
+8675526585726
sales@damslab.com
DESCRIPTION
Technical Specification for Performance Testing Device of Electric Fan
Purpose: According to the technical specifications of BSENIAEC60879:2019 and GB/T13380-2015:
1 Scope of application (applicable standards)
The requirements for this air volume testing device are based on the convenience of walking, and because the testing methods are basically the same, it can meet the air volume testing requirements of table fans, wall fans, floor fans, and column fans. Four anemometers are used to collect wind speed (two anemometers are added in the vertical direction on top of the original two horizontal anemometers on the test plane) to represent the average wind speed on the same ring.

2 Main technical parameters and functions
2.1 Main Technical Parameters
Can meet the air volume testing requirements for table fans, wall fans, floor fans, and column fans
Laboratory size: (small fan 4500 * 4500 * 3000) Unit: millimeters
2.2 Main functions
Used for testing wind speed, temperature, humidity, electrical parameters (voltage/current/power/power factor), speed, and time
3 Technical Requirements
3.1 Scope of Application (Unit: Millimeters)
Table fan blade diameter 200230250300350400450500
Bi fan blade diameter 250300350400450500
Terrace fan blade diameter 300350400450500
Floor fan blade diameter 300350400450600600
Rotating blade fan blade diameter 200230250300350400450500
1. The device meets the requirements of IEC60879 standard for air volume testing, with a reasonable design, high degree of automation, convenient use, durability, and load-bearing and anti vibration capabilities;
2. Test scope: ceiling fan;
3. Test parameters and items: temperature, humidity, atmospheric pressure, wind speed, air volume, input power, energy efficiency value.
4. The system adopts computer control and can display the wind speed value of each testing point. Generally, one testing point is set every 3 minutes (including positioning, delay of about 1 minute, and testing time of about 2 minutes). The average wind speed and point air volume of each circle are also displayed,
It can automatically generate detection results and process curves, and print them out.
5. During the experiment, measurements should be taken from two points approximately 40mm away from the axis of the fan blade, and moved in increments of 80mm along a horizontal straight line towards both sides until the measured average wind speed drops below 9m/min;
6. The fan mounting bracket and anemometer base are equipped with a universal adjustable pan tilt, and the installation height can be easily adjusted within the required range;
7. German Detu 435-2 type impeller anemometer, impeller diameter 100mm; 4 in total;
8. The system should be equipped with a multifunctional electricity meter that can measure voltage, current (true effective value), and power, as well as a 500VA variable frequency (± 1%) voltage regulator