QB/T5364 Test Chamber for Air Purifiers GB 4706.45 Safety of Household and Similar Electrical Appliances Special Requirements for Air Purifiers GB/T18801 Air Purifiers GB/T 18883 Indoor Air Quality Standard GB 21551.3 Special Requirements for Antibacterial, Sterilization, and Purification Functions of Household and Similar Electrical Appliances Air Purifiers
+8675526585726
sales@damslab.com
DESCRIPTION
QB/T5364 Test Chamber for Air Purifier Testing
GB 4706.45Special requirements for the safety of air purifiers for household and similar electrical appliancesGB/T18801air purifier
GB/T 18883Indoor Air Quality StandardsGB 21551.3 Special requirements for antibacterial, sterilizing, and purifying air purifiers for household and similar electrical appliances
Project Name |
Technical parameters and requirements |
Test cabin volume |
30m3. |
Test cabin size |
3.5 m×3.4 m×2.5 m = 29.75m3Allow ±0.5m3Deviation. |
temperature and humidity |
Standard temperature(23±2)℃, relative humidity(50±10)%The temperature is18℃~28Adjustable between ℃, relative humidity within30%~70%Adjustable between them. |
framework |
76 mm×44 mmStainless steel profiles, installed on the floor. |
wall |
Using thickness as5mmFloatation flat glass. |
floor |
Using thickness as3mmStainless steel plate, sturdy and beautiful. |
roof panel |
Using thickness as3mmStainless steel plate, sturdy and beautiful. |
sealing material |
Use silicone rubber strips and glass sealant. |
Sampling tube material |
Stainless steel or polytetrafluoroethylene should be equipped with four injection ports and four sampling ports. The length of the import tube should be(400~500)mm. |
ceiling fan |
Stainless steel ceiling fan with a diameter of1.4mSan Ye. Ensure that the mixing degree inside the environmental chamber reaches80%The above. |
circulating fan |
(500-700)m3/h, diameter20cmInstallation location: off the ground1.5m, away from the back wall0.4m. |
Circulating purification module |
Circulating purification module, which can quickly(<5min)Purify the air at the high concentration limit in the test chamber to meet the Indoor Air Quality Standards(GB/T 18883)The air; Can quickly(<5min)Purify the air with normal concentration inside the test chamber (equal to the concentration outside the chamber) to meet the requirementsGB/T 18801Air with standard background concentration requirements. |
exhaust fan |
ventilation rate900 m3/h. |
airtightness |
The air leakage rate inside the test chamber should be less than0.05 h-1. (Natural attenuation experiment) |
Mixing degree |
greater than80%. |
Adsorption test |
The natural decay rate of toluene is less than0.05h-1. (Natural attenuation experiment) |
Background concentration |
Equipped with a circulating purification module, it can quickly process the background concentration to below the national standardGB/T 18883The requirements in. |
data acquisition and processing |
Collecting electronic instrument signals and concentrating them into computer output, usableexcelTable processing yields standard test results, saving testing costs and improving testing efficiency. |